NormalPulseVoltammetry

From Onto-Wiki
Category:OSW3c3972f68e1d454ba19848173ba2232b
NormalPulseVoltammetry [OSW3c3972f68e1d454ba19848173ba2232b]
ID OSW3c3972f68e1d454ba19848173ba2232b
UUID 3c3972f6-8e1d-454b-a198-48173ba2232b
Label NormalPulseVoltammetry
Machine compatible name NormalPulseVoltammetry
Statements (outgoing)
Statements (incoming)

Description

Voltammetry in which potential pulses of amplitude increasing by a constant increment and with a pulse width of 2 to 200 ms are superimposed on a constant initial potential.

Item
Type(s)/Category(s) EmmoTerm
Term
EmmoTerm
Comment
  • Normal pulse polarography is NPV in which a dropping mercury electrode is used as the working electrode. A pulse is applied just before the mechanically enforced end of the drop. The pulse width is usually 10 to 20 % of the drop time. The drop dislodgment is synchro- nized with current sampling, which is carried out just before the end of the pulse, as in NPV. [en]
  • Sigmoidal wave-shaped voltammograms are obtained. [en]
  • The current is sampled at the end of the pulse and then plotted versus the potential of the pulse. [en]
  • The current is sampled just before the end of the pulse, when the charging current is greatly diminished. In this way, the ratio of faradaic current to charging current is enhanced and the negative influence of charging current is partially eliminated. Due to the improved signal (faradaic current) to noise (charging current) ratio, the limit of detec- tion is lowered. [en]
  • The sensitivity of NPV is not affected by the reversibility of the electrode reaction of the analyte. [en]
Superclass
  • Voltammetry
  • Alternative label
  • NPV [en]
  • URIhttp://emmo.info/electrochemistry#electrochemistry_3c3972f6_8e1d_454b_a198_48173ba2232b
    jsondata
    uuid"3c3972f6-8e1d-454b-a198-48173ba2232b"
    name"NormalPulseVoltammetry"
    label
    text"NormalPulseVoltammetry"
    lang"en"
    description
    text"Voltammetry in which potential pulses of amplitude increasing by a constant increment and with a pulse width of 2 to 200 ms are superimposed on a constant initial potential."
    lang"en"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    uri"http://emmo.info/electrochemistry#electrochemistry_3c3972f6_8e1d_454b_a198_48173ba2232b"
    altLabel
    text"NPV"
    lang"en"
    comment
    text"Normal pulse polarography is NPV in which a dropping mercury electrode is used as the working electrode. A pulse is applied just before the mechanically enforced end of the drop. The pulse width is usually 10 to 20 % of the drop time. The drop dislodgment is synchro- nized with current sampling, which is carried out just before the end of the pulse, as in NPV."
    lang"en"
    text"Sigmoidal wave-shaped voltammograms are obtained."
    lang"en"
    text"The current is sampled at the end of the pulse and then plotted versus the potential of the pulse."
    lang"en"
    text"The current is sampled just before the end of the pulse, when the charging current is greatly diminished. In this way, the ratio of faradaic current to charging current is enhanced and the negative influence of charging current is partially eliminated. Due to the improved signal (faradaic current) to noise (charging current) ratio, the limit of detec- tion is lowered."
    lang"en"
    text"The sensitivity of NPV is not affected by the reversibility of the electrode reaction of the analyte."
    lang"en"
    subClassOf
    "http://emmo.info/electrochemistry#electrochemistry_270f239e_33cb_4c6d_a41c_875ec1262d62"

    This category currently contains no pages or media.