Description

Voltammetry in which a square-wave potential waveform is superimposed on an underlying linearly varying potential ramp or staircase ramp. The current is sampled just before the end of the forward- going pulse and of the backward-going pulse and the difference of the two sampled currents is plotted versus the applied potential of the potential or staircase ramp. The square-wave voltammogram is peak- shaped.

Item
Type(s)/Category(s) EmmoTerm
Term
EmmoTerm
Comment
  • Most instruments show plots of the current at the end of the forward-going pulse and of the backward-going pulse vs. the potential, as well as their difference. This can give valuable information on the kinetics of the electrode reaction and the electrode process. [en]
  • The sensitivity of SWV depends on the reversibility of the electrode reaction of the analyte. [en]
Superclass
  • Voltammetry
  • Alternative label
  • OSWV [en]
  • Osteryoung square-wave voltammetry [en]
  • SWV [en]
  • URIhttp://emmo.info/electrochemistry#electrochemistry_042d2282_bd2d_4874_b896_2d9dd06b54dd
    jsondata
    uuid"042d2282-bd2d-4874-b896-2d9dd06b54dd"
    name"SquareWaveVoltammetry"
    label
    text"SquareWaveVoltammetry"
    lang"en"
    description
    text"Voltammetry in which a square-wave potential waveform is superimposed on an underlying linearly varying potential ramp or staircase ramp. The current is sampled just before the end of the forward- going pulse and of the backward-going pulse and the difference of the two sampled currents is plotted versus the applied potential of the potential or staircase ramp. The square-wave voltammogram is peak- shaped."
    lang"en"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    uri"http://emmo.info/electrochemistry#electrochemistry_042d2282_bd2d_4874_b896_2d9dd06b54dd"
    altLabel
    text"OSWV"
    lang"en"
    text"Osteryoung square-wave voltammetry"
    lang"en"
    text"SWV"
    lang"en"
    comment
    text"Most instruments show plots of the current at the end of the forward-going pulse and of the backward-going pulse vs. the potential, as well as their difference. This can give valuable information on the kinetics of the electrode reaction and the electrode process."
    lang"en"
    text"The sensitivity of SWV depends on the reversibility of the electrode reaction of the analyte."
    lang"en"
    subClassOf
    "http://emmo.info/electrochemistry#electrochemistry_270f239e_33cb_4c6d_a41c_875ec1262d62"