ReferenceElectrode

Category:OSW7729c34e1ae9403db9331765885e7f29
ReferenceElectrode [OSW7729c34e1ae9403db9331765885e7f29]
ID OSW7729c34e1ae9403db9331765885e7f29
UUID 7729c34e-1ae9-403d-b933-1765885e7f29
Label ReferenceElectrode
Machine compatible name ReferenceElectrode
Statements (outgoing)
Statements (incoming)

Description

No description found
Item
Type(s)/Category(s) EmmoTerm
Term
EmmoTerm
Comment
  • Electrode that maintains an essentially constant potential under the conditions prevailing in an electrochemical measurement, and that serves for observation, measurement, or control of the potential of the indicator or working electrode. [en]
  • Electrode with a well-defined and constant equilibrium potential with respect to which it is possible to measure or calculate electrode potentials of other electrodes by including them in an appropriate electrochemical cell. [en]
  • In potentiometry, under zero current condition, the essentially constant potential is achieved by ensuring a constant composition of solution in contact with the electrode forming a half-cell. Practical reference half-cells are generally non-polarizable electrodes of the 2nd kind (metal | insoluble salt | ion), constructed so that their electrolyte solutions serve as salt bridges to the solutions under investigation. [en]
  • “Double” junction reference electrodes are recommended when the reference electrolyte contains interfering components. [en]
URIhttp://emmo.info/electrochemistry#electrochemistry_7729c34e_1ae9_403d_b933_1765885e7f29
Superclass
  • NonPolarizableElectrode
  • jsondata
    uuid"7729c34e-1ae9-403d-b933-1765885e7f29"
    name"ReferenceElectrode"
    label
    text"ReferenceElectrode"
    lang"en"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    uri"http://emmo.info/electrochemistry#electrochemistry_7729c34e_1ae9_403d_b933_1765885e7f29"
    comment
    text"Electrode that maintains an essentially constant potential under the conditions prevailing in an electrochemical measurement, and that serves for observation, measurement, or control of the potential of the indicator or working electrode."
    lang"en"
    text"Electrode with a well-defined and constant equilibrium potential with respect to which it is possible to measure or calculate electrode potentials of other electrodes by including them in an appropriate electrochemical cell."
    lang"en"
    text"In potentiometry, under zero current condition, the essentially constant potential is achieved by ensuring a constant composition of solution in contact with the electrode forming a half-cell. Practical reference half-cells are generally non-polarizable electrodes of the 2nd kind (metal | insoluble salt | ion), constructed so that their electrolyte solutions serve as salt bridges to the solutions under investigation."
    lang"en"
    text"“Double” junction reference electrodes are recommended when the reference electrolyte contains interfering components."
    lang"en"
    subClassOf
    "http://emmo.info/electrochemistry#electrochemistry_9f466223_e20a_474d_ac4d_6d4b6131c275"

    This category currently contains no pages or media.